Battery life

Battery life depends on the logger configuration, installed sensors, operating conditions, and communication settings, so the actual operating time may vary significantly between applications. Efento NB-IoT loggers are available with different battery options, including an 8,500 mAh battery pack for IP30/IP65 variants and a 38,000 mAh high-capacity battery pack for the IP67 variant. Battery life values should therefore be treated as estimates rather than guaranteed operating times.

Battery life calculator

We have developed a battery life calculator that can be used to estimate the expected battery consumption and operating time of the logger based on selected configuration parameters.

Using the calculator

1

Select the logger model

Select a device from the list or search for it by name or EAN.

2

Configure the logger

Adjust the available configuration parameters to match the intended logger setup.

3

Review the results

The calculator automatically updates the estimated battery life based on the selected configuration and NB-IoT coverage conditions.

Calculator inputs

The calculator uses the following configuration inputs for all logger models:

  • Measurement interval

  • NB-IoT transmission interval

  • Bluetooth (BLE)

For 4–20 mA and 0–10 V loggers, an additional measurement calibration field is available to match the characteristics of the connected input.

Battery life results

The results also show the estimated battery life for three NB-IoT coverage conditions:

  • ECL0 (good coverage)

  • ECL1 (medium coverage)

  • ECL2 (poor coverage)

This makes it possible to see how network conditions may affect the expected operating time of the logger.

The energy usage chart shows the estimated contribution of individual device functions, such as measurements, NB-IoT transmissions, bluetooth, and sleep mode, to the overall power consumption. This helps identify which settings have the greatest impact on battery life and which parameters can be adjusted to extend the expected operating time. If a longer operating time is required, you can use this breakdown to determine which configuration parameters should be adjusted to reduce energy consumption.

Battery life considerations

The main factors affecting battery life are:

  • Signal quality – the worse the signal quality, the more retransmissions are needed to send the data to the server. The number of retransmissions is represented by the ECL parameter, and battery life is significantly reduced at higher ECL values (1 or 2).

  • Transmission interval – the more frequent the transmissions, the shorter the battery life.

  • Bluetooth interface – a Bluetooth interface that is always on reduces battery life. You can set the logger to switch off the Bluetooth interface automatically after a selected period of time.

  • ACK interval and rules – transmissions confirmed by the server and additional transmissions triggered by rules increase energy consumption.

  • Ambient temperature – at lower temperatures, batteries discharge faster. The logger should not operate outside the temperature range specified in its technical card.

  • Type of installed sensors – different measurement modules have different power requirements, so battery life depends on the type of sensors used in the logger.

  • FOTA updates – firmware updates performed over the cellular network also increase energy consumption.

  • Battery characteristics – battery lifetime is also affected by the natural physical and chemical processes occurring inside the battery. Battery-life calculations are therefore approximate.

Low battery

When the battery voltage drops below a safe level, the logger reports the low battery status over Bluetooth and to the server. The voltage thresholds and device behavior depend on the type of battery used.

Loggers with a replaceable battery

In loggers powered by a 3.6 V replaceable battery pack, replace the battery as soon as the low battery status is reported.

The factory-configured voltage thresholds are:

  • Below 3300 mV (low battery): the logger reports the low battery status over Bluetooth and to the server. It continues operating normally.

  • Below 2200 mV (switch off): the logger switches off completely to protect the device from operating at an excessively low voltage. To restore operation, replace the battery and switch the logger on.

Loggers with a rechargeable battery

In loggers equipped with a rechargeable battery, connect the external power supply or a USB charger as soon as the low battery status is reported.

The factory-configured voltage thresholds are:

  • Below 3800 mV (low battery): the logger reports the low battery status over Bluetooth and to the server. It continues operating normally.

  • Below 3700 mV (hibernation): the logger sends the last data to the server and enters hibernation mode. It stops taking measurements and sending data to protect the battery from deep discharge. When stable power is connected for at least 20 seconds, the logger restarts and resumes normal operation automatically.

  • Below 3600 mV (switch off): the logger switches off completely. To restore operation, connect the power supply and switch the logger on manually.

The voltage thresholds are factory settings. Hibernation mode is available in loggers with firmware 07.02.00 or later

Last updated