> For the complete documentation index, see [llms.txt](https://docs.efento.io/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.efento.io/nb-iot-loggers/configuration/sensor-specific-settings/water-rope.md).

# Water rope

Efento water rope sensors detect the presence of water by monitoring changes in the electrical signal measured by the external sensing rope.

The available settings allow you to adjust the detection sensitivity and define how the logger interprets the measured signal. Efento water leak sensors are factory-calibrated, so no initial calibration is required.

## **Configurable parameters**

| Parameter             | Description                                                                                                                                                                                                                                                                                                   | Configuration Options                                            |
| --------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ---------------------------------------------------------------- |
| **Reversed logic**    | Inverts the interpretation of the configured threshold range. When disabled, the logger reports no leak while the measurement remains within the defined minimum and maximum thresholds. When enabled, the interpretation is reversed and a leak is reported while the measurement remains within this range. | <p></p><p>Enabled (ON) / Disabled (OFF)<br>Default: Disabled</p> |
| **Minimum threshold** | The lower boundary (in percentage of supply voltage) for the condition check.                                                                                                                                                                                                                                 | Range: 0 to 100 % (must not be greater than Maximum Threshold).  |
| **Maximum threshold** | The upper boundary (in percentage of supply voltage) for the condition check.                                                                                                                                                                                                                                 | Range: 0 to 100 % (must not be less than Minimum Threshold).     |

### **Sensitivity**

When the sensing rope is dry, the measured voltage remains within the configured normal range. When the rope becomes wet, the voltage decreases. If the measured value falls outside the configured threshold range, the logger changes its state accordingly.

The sensitivity can be adjusted using the **Minimum threshold** and **Maximum threshold** parameters. If the sensor does not react sensitively enough when the rope is wet, the minimum threshold can be increased. If an alarm is triggered while the rope is dry, first check the probe for damage and then adjust the thresholds if necessary.

![](https://content.gitbook.com/content/GPFUI36OraG706yJS7dJ/blobs/6NvrFTpvZIsvlvjIOMT7/Unknown%20image)

## **Configuration using the Efento mobile application**

All parameters described above can be configured using the Efento mobile application in the **Nearby Devices** section.

Connect to the logger, tap the gear icon, open **Channel settings**, and select **Settings** for the required channel.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.efento.io/nb-iot-loggers/configuration/sensor-specific-settings/water-rope.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.