> For the complete documentation index, see [llms.txt](https://docs.efento.io/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.efento.io/nb-iot-loggers/configuration/sensor-specific-settings/thermocouples.md).

# Thermocouples

Thermocouples connected to the Efento logger must be configured according to the type and characteristics of the probe used.

The logger also provides automatic **cold junction compensation** using an internal reference sensor. This function is preconfigured and does not require any user setup.

When connecting a thermocouple, make sure the probe polarity is correct and use extension or compensation cables suitable for the selected thermocouple type.

The configurable parameters are described below.

## **Configurable parameters**

| Parameter                  | Description                                                                                                                                                                                                                                                                                                                                       | Configuration Options                                   |
| -------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------- |
| **Thermocouple type**      | Specifies the type of thermocouple probe connected to the terminal block. Each type utilizes a specific combination of metal alloys and has a distinct Seebeck voltage-to-temperature characteristic.                                                                                                                                             | Type J, K, E, N, R, S, T, B                             |
| **Open circuit current**   | Sets the pulsed test current used by the device to detect open-circuit faults (broken wire, loose connection, or probe failure). For very long leads or higher-resistance thermocouple circuits, selecting a lower current prevents false open-circuit fault triggers.                                                                            | 10 µA, 100 µA, 500 µA, 1 mA                             |
| **Extra delay multiplier** | Adds a settling delay (in 100 µs increments) between excitation and measurement. This compensates for extra capacitance introduced when using long, shielded, or heavily filtered thermocouple extension cables.                                                                                                                                  | 0 to 255 (0 to 25,500 µs)                               |
| **PT logger type**         | <p>Specifies the RTD sensor type used internally on the logger expansion board for Cold Junction Compensation (CJC). In Efento loggers, this is an onboard platinum RTD sensor placed near the terminal block to measure junction temperature.<br><em>(Preconfigured at the factory; do not change unless instructed by Efento Support).</em></p> | PT10, PT50, PT100, PT200, PT500, PT1000                 |
| **Logger curve type**      | <p>Defines the mathematical resistance-to-temperature ($R$-$T$) relationship for the internal reference RTD sensor used for Cold Junction Compensation.<br><em>(Preconfigured at the factory; do not change unless instructed by Efento Support).</em></p>                                                                                        | European standard, American, Japanese, ITS-90           |
| **Excitation current**     | <p>Defines the excitation current supplied to the onboard Cold Junction Compensation reference sensor during measurement.<br><em>(Preconfigured at the factory; do not change unless instructed by Efento Support).</em></p>                                                                                                                      | 5 µA, 10 µA, 25 µA, 50 µA, 100 µA, 250 µA, 500 µA, 1 mA |

## **Configuration using the Efento mobile application**

All parameters described above can be configured using the Efento mobile application in the **Nearby Devices** section.

Connect to the logger, tap the gear icon, open **Channel settings**, and select **Settings** for the required channel.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.efento.io/nb-iot-loggers/configuration/sensor-specific-settings/thermocouples.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.