Encryption
You can protect Bluetooth communication with the logger by setting an encryption key. When encryption is enabled, the logger remains visible in the list of nearby devices in the Efento mobile application, but its measurement data and configuration cannot be accessed without the correct key.
This includes current measurements, data stored in the logger’s internal memory and device settings. As a result, only authorized personnel can access the logger and modify its configuration.
When connecting to an encrypted logger in the Efento mobile application for the first time, you will be prompted to enter the encryption key. After it is entered successfully, the application stores it on that device, so it does not need to be entered again for subsequent connections.
The encryption key can be up to 16 characters long. For security reasons, the key cannot be read from the logger, neither via Bluetooth nor from the server.
The encryption key can be set, changed or removed via Bluetooth (the current key is required) or remotely, in the configuration sent from the server.
The encryption key protects only the Bluetooth communication. It does not affect the data sent over the cellular network to Efento Cloud or the customer's server (see Security).

If the logger communication is encrypted, only devices with a proper encryption key can read its measurements. Devices without the encryption key are not able to read the data.
Configurable parameters
Encryption
A security key used to protect access to the logger over Bluetooth. Without the correct key, measurement data and device settings cannot be accessed or modified.
Max 16 characters. Supported characters: A-Z a-z 0-9 (space) ! " # $ % & ' ( ) * + , - . / : ; < = > ? @ [ ] ^ _ { | } ~`
Configuration methods
You can configure these settings in several ways:
Remotely from server – see the Integrations section for information on configuring the logger from your own server.
From the Efento mobile application – connect to the logger and follow the relevant configuration path in the app.
Factory preconfiguration – on request, Efento can supply devices with selected settings already configured according to your requirements. See Factory preconfiguration for the list of parameters that can be configured before shipment.
Configuration using the Efento mobile application
Setting the encryption key
To set the encryption key in the Efento mobile app, connect to the logger and tap the gear icon. Select Encryption status, choose “Enabled”, enter the encryption key, and save the settings.
To disable encryption, follow the same steps and select “Disabled” in the Encryption status settings, then save the configuration.
Forgotten encryption key
Store the encryption key in a safe place. If the key is lost, it cannot be recovered, neither by the user nor by Efento Support. The only way to regain access to the logger is to restore its factory settings:
Try to connect to the logger in the Efento mobile application. After entering a wrong key 3 times, the "Forgot your encryption key?" option appears below the key field.
Tap "Restore factory settings".
Confirm the operation.